clang-format

This commit is contained in:
tyeth 2025-08-20 14:54:32 +01:00
parent 32f85f7b47
commit dc5ff4ae9f
2 changed files with 77 additions and 54 deletions

View file

@ -550,10 +550,13 @@ bool WipperSnapper_Component_I2C::initI2CDevice(
drivers.push_back(_mlx90632d);
WS_DEBUG_PRINTLN("MLX90632 Initialized Successfully!");
} else if (strcmp("mlx90632d_ext", msgDeviceInitReq->i2c_device_name) == 0) {
_mlx90632d_ext = new WipperSnapper_I2C_Driver_MLX90632D(this->_i2c, i2cAddress);
_mlx90632d_ext =
new WipperSnapper_I2C_Driver_MLX90632D(this->_i2c, i2cAddress);
// set extended range
if (!_mlx90632d_ext->begin() || !_mlx90632d_ext->ConfigureAndPrintSensorInfo(true)) {
WS_DEBUG_PRINTLN("ERROR: Failed to initialize MLX90632D with extended range!");
if (!_mlx90632d_ext->begin() ||
!_mlx90632d_ext->ConfigureAndPrintSensorInfo(true)) {
WS_DEBUG_PRINTLN(
"ERROR: Failed to initialize MLX90632D with extended range!");
_busStatusResponse =
wippersnapper_i2c_v1_BusResponse_BUS_RESPONSE_DEVICE_INIT_FAIL;
return false;

View file

@ -71,7 +71,8 @@ public:
/*!
@brief Configures the MLX90632 sensor and prints its information.
@param extendedInsteadOfMedicalRange
If true, configures the sensor for extended temperature range/acc.
If true, configures the sensor for extended temperature
range/acc.
@returns True if configuration fetching and setting were successful.
*/
/*******************************************************************************/
@ -79,7 +80,9 @@ public:
// Reset the device
if (!_mlx90632->reset()) {
WS_PRINTER.println(F("Device reset failed"));
while (1) { delay(10); }
while (1) {
delay(10);
}
}
WS_PRINTER.println(F("Device reset: SUCCESS"));
@ -119,10 +122,14 @@ public:
// Set and get mode - choose one:
WS_PRINTER.println(F("\n--- Mode Settings ---"));
if (!_mlx90632->setMode(MLX90632_MODE_CONTINUOUS)) {
// if (!_mlx90632->setMode(MLX90632_MODE_STEP)) { // Uncomment for step mode testing
// if (!_mlx90632->setMode(MLX90632_MODE_SLEEPING_STEP)) { // Uncomment for sleeping step mode testing
// if (!_mlx90632->setMode(MLX90632_MODE_STEP)) { // Uncomment
// for step mode testing if
// (!_mlx90632->setMode(MLX90632_MODE_SLEEPING_STEP)) { // Uncomment for
// sleeping step mode testing
WS_PRINTER.println(F("Failed to set mode"));
while (1) { delay(10); }
while (1) {
delay(10);
}
}
// TODO: use Step mode?
@ -149,15 +156,24 @@ public:
if (accuracy == 1) {
// Set and get measurement select (medical)
WS_PRINTER.println(F("\n--- Measurement Select Settings ---"));
if (!extendedInsteadOfMedicalRange && !_mlx90632->setMeasurementSelect(MLX90632_MEAS_MEDICAL)) {
if (!extendedInsteadOfMedicalRange &&
!_mlx90632->setMeasurementSelect(MLX90632_MEAS_MEDICAL)) {
WS_PRINTER.println(F("Failed to set measurement select to Medical"));
while (1) { delay(10); }
} else if (extendedInsteadOfMedicalRange && !_mlx90632->setMeasurementSelect(MLX90632_MEAS_EXTENDED_RANGE)) {
WS_PRINTER.println(F("Failed to set measurement select to Extended Range"));
while (1) { delay(10); }
while (1) {
delay(10);
}
} else if (extendedInsteadOfMedicalRange &&
!_mlx90632->setMeasurementSelect(
MLX90632_MEAS_EXTENDED_RANGE)) {
WS_PRINTER.println(
F("Failed to set measurement select to Extended Range"));
while (1) {
delay(10);
}
}
mlx90632_meas_select_t currentMeasSelect = _mlx90632->getMeasurementSelect();
mlx90632_meas_select_t currentMeasSelect =
_mlx90632->getMeasurementSelect();
WS_PRINTER.print(F("Current measurement select: "));
switch (currentMeasSelect) {
case MLX90632_MEAS_MEDICAL:
@ -175,7 +191,9 @@ public:
WS_PRINTER.println(F("\n--- Refresh Rate Settings ---"));
if (!_mlx90632->setRefreshRate(MLX90632_REFRESH_2HZ)) {
WS_PRINTER.println(F("Failed to set refresh rate to 2Hz"));
while (1) { delay(10); }
while (1) {
delay(10);
}
}
mlx90632_refresh_rate_t currentRefreshRate = _mlx90632->getRefreshRate();
@ -213,7 +231,9 @@ public:
WS_PRINTER.println(F("\\n--- Starting Continuous Measurements ---"));
if (!_mlx90632->resetNewData()) {
WS_PRINTER.println(F("Failed to reset new data flag"));
while (1) { delay(10); }
while (1) {
delay(10);
}
}
return true;
}
@ -266,12 +286,12 @@ public:
WS_PRINTER.println(); // Add blank line between readings
} else {
WS_PRINTER.println(F("No new data available, skipping read"));
}
// Check if we need to trigger a new measurement for step modes
mlx90632_mode_t currentMode = _mlx90632->getMode();
if (currentMode == MLX90632_MODE_STEP || currentMode == MLX90632_MODE_SLEEPING_STEP) {
if (currentMode == MLX90632_MODE_STEP ||
currentMode == MLX90632_MODE_SLEEPING_STEP) {
// Trigger single measurement (SOC bit) for step modes
if (!_mlx90632->startSingleMeasurement()) {
WS_PRINTER.println(F("Failed to start single measurement"));