clang-format
This commit is contained in:
parent
32f85f7b47
commit
dc5ff4ae9f
2 changed files with 77 additions and 54 deletions
|
|
@ -550,10 +550,13 @@ bool WipperSnapper_Component_I2C::initI2CDevice(
|
|||
drivers.push_back(_mlx90632d);
|
||||
WS_DEBUG_PRINTLN("MLX90632 Initialized Successfully!");
|
||||
} else if (strcmp("mlx90632d_ext", msgDeviceInitReq->i2c_device_name) == 0) {
|
||||
_mlx90632d_ext = new WipperSnapper_I2C_Driver_MLX90632D(this->_i2c, i2cAddress);
|
||||
_mlx90632d_ext =
|
||||
new WipperSnapper_I2C_Driver_MLX90632D(this->_i2c, i2cAddress);
|
||||
// set extended range
|
||||
if (!_mlx90632d_ext->begin() || !_mlx90632d_ext->ConfigureAndPrintSensorInfo(true)) {
|
||||
WS_DEBUG_PRINTLN("ERROR: Failed to initialize MLX90632D with extended range!");
|
||||
if (!_mlx90632d_ext->begin() ||
|
||||
!_mlx90632d_ext->ConfigureAndPrintSensorInfo(true)) {
|
||||
WS_DEBUG_PRINTLN(
|
||||
"ERROR: Failed to initialize MLX90632D with extended range!");
|
||||
_busStatusResponse =
|
||||
wippersnapper_i2c_v1_BusResponse_BUS_RESPONSE_DEVICE_INIT_FAIL;
|
||||
return false;
|
||||
|
|
|
|||
|
|
@ -26,7 +26,7 @@
|
|||
*/
|
||||
/**************************************************************************/
|
||||
class WipperSnapper_I2C_Driver_MLX90632D : public WipperSnapper_I2C_Driver {
|
||||
public:
|
||||
public:
|
||||
/*******************************************************************************/
|
||||
/*!
|
||||
@brief Constructor for an MLX90632 sensor.
|
||||
|
|
@ -71,7 +71,8 @@ public:
|
|||
/*!
|
||||
@brief Configures the MLX90632 sensor and prints its information.
|
||||
@param extendedInsteadOfMedicalRange
|
||||
If true, configures the sensor for extended temperature range/acc.
|
||||
If true, configures the sensor for extended temperature
|
||||
range/acc.
|
||||
@returns True if configuration fetching and setting were successful.
|
||||
*/
|
||||
/*******************************************************************************/
|
||||
|
|
@ -79,7 +80,9 @@ public:
|
|||
// Reset the device
|
||||
if (!_mlx90632->reset()) {
|
||||
WS_PRINTER.println(F("Device reset failed"));
|
||||
while (1) { delay(10); }
|
||||
while (1) {
|
||||
delay(10);
|
||||
}
|
||||
}
|
||||
WS_PRINTER.println(F("Device reset: SUCCESS"));
|
||||
|
||||
|
|
@ -119,13 +122,17 @@ public:
|
|||
// Set and get mode - choose one:
|
||||
WS_PRINTER.println(F("\n--- Mode Settings ---"));
|
||||
if (!_mlx90632->setMode(MLX90632_MODE_CONTINUOUS)) {
|
||||
// if (!_mlx90632->setMode(MLX90632_MODE_STEP)) { // Uncomment for step mode testing
|
||||
// if (!_mlx90632->setMode(MLX90632_MODE_SLEEPING_STEP)) { // Uncomment for sleeping step mode testing
|
||||
// if (!_mlx90632->setMode(MLX90632_MODE_STEP)) { // Uncomment
|
||||
// for step mode testing if
|
||||
// (!_mlx90632->setMode(MLX90632_MODE_SLEEPING_STEP)) { // Uncomment for
|
||||
// sleeping step mode testing
|
||||
WS_PRINTER.println(F("Failed to set mode"));
|
||||
while (1) { delay(10); }
|
||||
while (1) {
|
||||
delay(10);
|
||||
}
|
||||
}
|
||||
|
||||
//TODO: use Step mode?
|
||||
// TODO: use Step mode?
|
||||
mlx90632_mode_t currentMode = _mlx90632->getMode();
|
||||
WS_PRINTER.print(F("Current mode: "));
|
||||
switch (currentMode) {
|
||||
|
|
@ -149,15 +156,24 @@ public:
|
|||
if (accuracy == 1) {
|
||||
// Set and get measurement select (medical)
|
||||
WS_PRINTER.println(F("\n--- Measurement Select Settings ---"));
|
||||
if (!extendedInsteadOfMedicalRange && !_mlx90632->setMeasurementSelect(MLX90632_MEAS_MEDICAL)) {
|
||||
if (!extendedInsteadOfMedicalRange &&
|
||||
!_mlx90632->setMeasurementSelect(MLX90632_MEAS_MEDICAL)) {
|
||||
WS_PRINTER.println(F("Failed to set measurement select to Medical"));
|
||||
while (1) { delay(10); }
|
||||
} else if (extendedInsteadOfMedicalRange && !_mlx90632->setMeasurementSelect(MLX90632_MEAS_EXTENDED_RANGE)) {
|
||||
WS_PRINTER.println(F("Failed to set measurement select to Extended Range"));
|
||||
while (1) { delay(10); }
|
||||
while (1) {
|
||||
delay(10);
|
||||
}
|
||||
} else if (extendedInsteadOfMedicalRange &&
|
||||
!_mlx90632->setMeasurementSelect(
|
||||
MLX90632_MEAS_EXTENDED_RANGE)) {
|
||||
WS_PRINTER.println(
|
||||
F("Failed to set measurement select to Extended Range"));
|
||||
while (1) {
|
||||
delay(10);
|
||||
}
|
||||
}
|
||||
|
||||
mlx90632_meas_select_t currentMeasSelect = _mlx90632->getMeasurementSelect();
|
||||
mlx90632_meas_select_t currentMeasSelect =
|
||||
_mlx90632->getMeasurementSelect();
|
||||
WS_PRINTER.print(F("Current measurement select: "));
|
||||
switch (currentMeasSelect) {
|
||||
case MLX90632_MEAS_MEDICAL:
|
||||
|
|
@ -175,7 +191,9 @@ public:
|
|||
WS_PRINTER.println(F("\n--- Refresh Rate Settings ---"));
|
||||
if (!_mlx90632->setRefreshRate(MLX90632_REFRESH_2HZ)) {
|
||||
WS_PRINTER.println(F("Failed to set refresh rate to 2Hz"));
|
||||
while (1) { delay(10); }
|
||||
while (1) {
|
||||
delay(10);
|
||||
}
|
||||
}
|
||||
|
||||
mlx90632_refresh_rate_t currentRefreshRate = _mlx90632->getRefreshRate();
|
||||
|
|
@ -213,7 +231,9 @@ public:
|
|||
WS_PRINTER.println(F("\\n--- Starting Continuous Measurements ---"));
|
||||
if (!_mlx90632->resetNewData()) {
|
||||
WS_PRINTER.println(F("Failed to reset new data flag"));
|
||||
while (1) { delay(10); }
|
||||
while (1) {
|
||||
delay(10);
|
||||
}
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
|
@ -235,7 +255,7 @@ public:
|
|||
*/
|
||||
/*******************************************************************************/
|
||||
bool ReadSensorData() {
|
||||
bool result=false;
|
||||
bool result = false;
|
||||
|
||||
// Only check new data flag - much more efficient for continuous mode
|
||||
if (_mlx90632->isNewData()) {
|
||||
|
|
@ -257,7 +277,7 @@ public:
|
|||
WS_PRINTER.print(_objectTemp, 4);
|
||||
WS_PRINTER.println(F(" °C"));
|
||||
}
|
||||
result=true;
|
||||
result = true;
|
||||
// Reset new data flag after reading
|
||||
if (!_mlx90632->resetNewData()) {
|
||||
WS_PRINTER.println(F("Failed to reset new data flag"));
|
||||
|
|
@ -266,12 +286,12 @@ public:
|
|||
WS_PRINTER.println(); // Add blank line between readings
|
||||
} else {
|
||||
WS_PRINTER.println(F("No new data available, skipping read"));
|
||||
|
||||
}
|
||||
|
||||
// Check if we need to trigger a new measurement for step modes
|
||||
mlx90632_mode_t currentMode = _mlx90632->getMode();
|
||||
if (currentMode == MLX90632_MODE_STEP || currentMode == MLX90632_MODE_SLEEPING_STEP) {
|
||||
if (currentMode == MLX90632_MODE_STEP ||
|
||||
currentMode == MLX90632_MODE_SLEEPING_STEP) {
|
||||
// Trigger single measurement (SOC bit) for step modes
|
||||
if (!_mlx90632->startSingleMeasurement()) {
|
||||
WS_PRINTER.println(F("Failed to start single measurement"));
|
||||
|
|
@ -293,7 +313,7 @@ public:
|
|||
/*******************************************************************************/
|
||||
bool getEventAmbientTemp(sensors_event_t *tempEvent) {
|
||||
if (ReadSensorData() && _deviceTemp != NAN) {
|
||||
//TODO: check max/min or error values in datasheet
|
||||
// TODO: check max/min or error values in datasheet
|
||||
// if (_deviceTemp < -40 || _deviceTemp > 125) {
|
||||
// WS_PRINTER.println(F("Invalid ambient temperature"));
|
||||
// return false;
|
||||
|
|
@ -323,7 +343,7 @@ public:
|
|||
return false; // sensor not read recently, return false
|
||||
}
|
||||
|
||||
protected:
|
||||
protected:
|
||||
double _deviceTemp; ///< Device temperature in Celsius
|
||||
double _objectTemp; ///< Object temperature in Celsius
|
||||
uint32_t _lastRead; ///< Last time the sensor was read in milliseconds
|
||||
|
|
|
|||
Loading…