# Copyright 2019-2020, Peter Bigot Consulting, LLC
|
|
# Copyright 2022 Nordic Semiconductor ASA
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
|
|
description: |
|
|
Voltage/Current Regulators
|
|
|
|
Properties are inherited from Linux. See
|
|
linux/Documentation/devicetree/bindings/regulator/regulator.yaml.
|
|
|
|
include: power.yaml
|
|
|
|
properties:
|
|
regulator-name:
|
|
type: string
|
|
description: A string used as a descriptive name for regulator outputs
|
|
|
|
regulator-init-microvolt:
|
|
type: int
|
|
description: Voltage set during initialisation
|
|
|
|
regulator-min-microvolt:
|
|
type: int
|
|
description: smallest voltage consumers may set
|
|
|
|
regulator-max-microvolt:
|
|
type: int
|
|
description: largest voltage consumers may set
|
|
|
|
regulator-microvolt-offset:
|
|
type: int
|
|
description: Offset applied to voltages to compensate for voltage drops
|
|
|
|
regulator-init-microamp:
|
|
type: int
|
|
description: Current set during initialisation
|
|
|
|
regulator-min-microamp:
|
|
type: int
|
|
description: smallest current consumers may set
|
|
|
|
regulator-max-microamp:
|
|
type: int
|
|
description: largest current consumers may set
|
|
|
|
regulator-input-current-limit-microamp:
|
|
type: int
|
|
description: maximum input current regulator allows
|
|
|
|
regulator-always-on:
|
|
type: boolean
|
|
description: boolean, regulator should never be disabled
|
|
|
|
regulator-boot-on:
|
|
type: boolean
|
|
description: |
|
|
bootloader/firmware enabled regulator.
|
|
It's expected that this regulator was left on by the bootloader.
|
|
If the bootloader didn't leave it on then OS should turn it on
|
|
at boot but shouldn't prevent it from being turned off later.
|
|
This property is intended to only be used for regulators where
|
|
software cannot read the state of the regulator.
|
|
|
|
regulator-boot-off:
|
|
type: boolean
|
|
description: |
|
|
Regulator should be disabled on boot.
|
|
|
|
regulator-allow-bypass:
|
|
type: boolean
|
|
description: allow the regulator to go into bypass mode
|
|
|
|
regulator-allow-set-load:
|
|
type: boolean
|
|
description: allow the regulator performance level to be configured
|
|
|
|
regulator-ramp-delay:
|
|
type: int
|
|
description: |
|
|
ramp delay for regulator(in uV/us) For hardware which supports disabling
|
|
ramp rate, it should be explicitly initialised to zero
|
|
(regulator-ramp-delay = <0>) for disabling ramp delay.
|
|
|
|
regulator-enable-ramp-delay:
|
|
type: int
|
|
description: |
|
|
The time taken, in microseconds, for the supply rail to reach the target
|
|
voltage, plus/minus whatever tolerance the board design requires. This
|
|
property describes the total system ramp time required due to the
|
|
combination of internal ramping of the regulator itself, and board design
|
|
issues such as trace capacitance and load on the supply.
|
|
|
|
regulator-settling-time-us:
|
|
type: int
|
|
description: |
|
|
Settling time, in microseconds, for voltage change if regulator have the
|
|
constant time for any level voltage change. This is useful when regulator
|
|
have exponential voltage change.
|
|
|
|
regulator-settling-time-up-us:
|
|
type: int
|
|
description: |
|
|
Settling time, in microseconds, for voltage increase if the regulator
|
|
needs a constant time to settle after voltage increases of any level. This
|
|
is useful for regulators with exponential voltage changes.
|
|
|
|
regulator-settling-time-down-us:
|
|
type: int
|
|
description: |
|
|
Settling time, in microseconds, for voltage decrease if the regulator
|
|
needs a constant time to settle after voltage decreases of any level. This
|
|
is useful for regulators with exponential voltage changes.
|
|
|
|
regulator-soft-start:
|
|
type: boolean
|
|
description: Enable soft start so that voltage ramps slowly
|
|
|
|
regulator-initial-mode:
|
|
type: int
|
|
description: |
|
|
Initial operating mode. The set of possible operating modes depends on the
|
|
capabilities of every hardware so each device binding documentation
|
|
explains which values the regulator supports.
|
|
|
|
regulator-allowed-modes:
|
|
type: array
|
|
description: |
|
|
List of operating modes that software is allowed to configure for the
|
|
regulator at run-time. Elements may be specified in any order. The set of
|
|
possible operating modes depends on the capabilities of every hardware so
|
|
each device binding document explains which values the regulator supports.
|
|
|
|
regulator-system-load:
|
|
type: int
|
|
description: |
|
|
Load in uA present on regulator that is not captured by any consumer
|
|
request.
|
|
|
|
regulator-pull-down:
|
|
type: boolean
|
|
description: Enable pull down resistor when the regulator is disabled.
|
|
|
|
regulator-over-current-protection:
|
|
type: boolean
|
|
description: Enable over current protection.
|
|
|
|
regulator-oc-protection-microamp:
|
|
type: int
|
|
description: |
|
|
Set over current protection limit. This is a limit where hardware performs
|
|
emergency shutdown. Zero can be passed to disable protection and value '1'
|
|
indicates that protection should be enabled but limit setting can be
|
|
omitted.
|
|
|
|
regulator-oc-error-microamp:
|
|
type: int
|
|
description: |
|
|
Set over current error limit. This is a limit where part of the hardware
|
|
probably is malfunctional and damage prevention is requested. Zero can be
|
|
passed to disable error detection and value '1' indicates that detection
|
|
should be enabled but limit setting can be omitted.
|
|
|
|
regulator-oc-warn-microamp:
|
|
type: int
|
|
description: |
|
|
Set over current warning limit. This is a limit where hardware is assumed
|
|
still to be functional but approaching limit where it gets damaged.
|
|
Recovery actions should be initiated. Zero can be passed to disable
|
|
detection and value '1' indicates that detection should be enabled but
|
|
limit setting can be omitted.
|
|
|
|
regulator-ov-protection-microvolt:
|
|
type: int
|
|
description: |
|
|
Set over voltage protection limit. This is a limit where hardware performs
|
|
emergency shutdown. Zero can be passed to disable protection and value '1'
|
|
indicates that protection should be enabled but limit setting can be
|
|
omitted. Limit is given as microvolt offset from voltage set to regulator.
|
|
|
|
regulator-ov-error-microvolt:
|
|
type: int
|
|
description: |
|
|
Set over voltage error limit. This is a limit where part of the hardware
|
|
probably is malfunctional and damage prevention is requested Zero can be
|
|
passed to disable error detection and value '1' indicates that detection
|
|
should be enabled but limit setting can be omitted. Limit is given as
|
|
microvolt offset from voltage set to regulator.
|
|
|
|
regulator-ov-warn-microvolt:
|
|
type: int
|
|
description: |
|
|
Set over voltage warning limit. This is a limit where hardware is assumed
|
|
still to be functional but approaching limit where it gets damaged.
|
|
Recovery actions should be initiated. Zero can be passed to disable
|
|
detection and value '1' indicates that detection should be enabled but
|
|
limit setting can be omitted. Limit is given as microvolt offset from
|
|
voltage set to regulator.
|
|
|
|
regulator-uv-protection-microvolt:
|
|
type: int
|
|
description: |
|
|
Set over under voltage protection limit. This is a limit where hardware
|
|
performs emergency shutdown. Zero can be passed to disable protection and
|
|
value '1' indicates that protection should be enabled but limit setting
|
|
can be omitted. Limit is given as microvolt offset from voltage set to
|
|
regulator.
|
|
|
|
regulator-uv-error-microvolt:
|
|
type: int
|
|
description: |
|
|
Set under voltage error limit. This is a limit where part of the hardware
|
|
probably is malfunctional and damage prevention is requested Zero can be
|
|
passed to disable error detection and value '1' indicates that detection
|
|
should be enabled but limit setting can be omitted. Limit is given as
|
|
microvolt offset from voltage set to regulator.
|
|
|
|
regulator-uv-warn-microvolt:
|
|
type: int
|
|
description: |
|
|
Set over under voltage warning limit. This is a limit where hardware is
|
|
assumed still to be functional but approaching limit where it gets
|
|
damaged. Recovery actions should be initiated. Zero can be passed to
|
|
disable detection and value '1' indicates that detection should be enabled
|
|
but limit setting can be omitted. Limit is given as microvolt offset from
|
|
voltage set to regulator.
|
|
|
|
regulator-temp-protection-kelvin:
|
|
type: int
|
|
description: |
|
|
Set over temperature protection limit. This is a limit where hardware
|
|
performs emergency shutdown. Zero can be passed to disable protection and
|
|
value '1' indicates that protection should be enabled but limit setting
|
|
can be omitted.
|
|
|
|
regulator-temp-error-kelvin:
|
|
type: int
|
|
description: |
|
|
Set over temperature error limit. This is a limit where part of the
|
|
hardware probably is malfunctional and damage prevention is requested Zero
|
|
can be passed to disable error detection and value '1' indicates that
|
|
detection should be enabled but limit setting can be omitted.
|
|
|
|
regulator-temp-warn-kelvin:
|
|
type: int
|
|
description: |
|
|
Set over temperature warning limit. This is a limit where hardware is
|
|
assumed still to be functional but approaching limit where it gets
|
|
damaged. Recovery actions should be initiated. Zero can be passed to
|
|
disable detection and value '1' indicates that detection should be enabled
|
|
but limit setting can be omitted.
|
|
|
|
regulator-active-discharge:
|
|
type: int
|
|
enum:
|
|
- 0
|
|
- 1
|
|
description: |
|
|
tristate, enable/disable active discharge of regulators. The values are:
|
|
0: Disable active discharge.
|
|
1: Enable active discharge.
|
|
Absence of this property will leave configuration to default.
|
|
|
|
regulator-max-step-microvolt:
|
|
type: int
|
|
description: |
|
|
Maximum difference between current and target voltages that can be changed
|
|
safely in a single step.
|
|
|
|
startup-delay-us:
|
|
type: int
|
|
description: Startup time, in microseconds
|
|
|
|
off-on-delay-us:
|
|
type: int
|
|
description: Off to on delay time, in microseconds
|